 HD320 series | Ultrasonic Level Meter|HD320 / HD323

 

Features

●Two-wire interface can suppress the cost of installation, wiring and operation.

What is two-wire system?

Two-wire system supplies electric power through the data line. Electrical wiring is completed only with two lines, power + data and ground.

 

●Four screen mode can be selected

●Large display is adopted for HD323 (Display size : 50 x 25mm, 49% larger than HD320)

●Mask function

Unnecessary signal can be eliminated from the received signal by manually.
Echo signal from existing structure positioned between sensor and target cause interference. Mask function removes these unnecessary echo effectively.

 

Usage

Measurement of liquid level in a tank
Measurement of sewage level inside pipes
Measurement of water level in lakes, ponds and rivers


   

 

Model No.

HD320

HD323

Number of channels

1

Frequency

50kHz

Measurement target

liquid

Measurement distance range

0.25 to 7.5m

Resolution

Measurement

1mm

Display

1mm

Accuracy

±0.25%F.S.
(±1.88cm)

Data update cycle

10sec

Sensor directive angle (beam angle)

14°(-6dB) / 10°-3dB)

Power source

Voltage

24VDC

Power consumption

0.6W

Display

Graphic LCD

Display size

28.1 x 9.1mm

50 x 25mm

Output

4-20 mA current

Resolution: 12 bits            
(Max. load resistance 500Ω 24V)

Ambient operating temperature

-20 to 70

Material

PP (polypropylene)

Protection

IP65 equivalent (without lid: IP20 equivalent)

Dimensions

dia. 93 x 110mm

Cable length

10m

Weight

350g

Mounting screw

G2 (PF2)


Do not use metal nut or metal flange. It may cause error on measurement.
* Please use nut or flange that made of plastic.

HD1200 | Ultrasonic Level meter

·         Advanced level sensing algorithm suppresses the noise level and artifacts and enabled stable measurement.

·         One main unit handles two sensors at once. Two different types of sensors can be installed and each may measures different range.

·         Data logging function to micro SD TM.

·         Flow measurement by measuring catchment level is possible.

 

Usage

·         Level control of liquid, powder or grains in a tank

·         Level measurement of pond, lake or river

·         Open channel flow measurement (catchment level)



 

 

Model No.

HD1200

Channel

2

Frequency

10 to 60 kHz (select by sensor)

Measurement object

liquid / powder

Resolution

Measurement

1 mm

display

1 mm

Accuracy

±0.25% F.S.

 Data refresh rate

2 sec. approx. (depends on sensor)

Power source

Voltage

100 to 240 V AC ±10 %

Power consumption

10 VA

Display

LCD with backlight

Output

Alarm

4 points / channel
250VAC, 5 A (relay contact)

4-20mA current

Resolution: 1/4000
(Max. load resistance 600Ω)

Interface

RS-485 (max. distance: 1200 m or less)
RS-232C (max. distance: 10 m or less)

Memory

microSDTM *1

Operation temperature

-20 to 70

Material

ABS

Protection

IP66 equivalent

Dimension (WxDxH mm)

17684237

Weight

1.8 kg

NOTE : Weir type flowmeter is available on CH1

*1 : microSDTM is a trademark of SD Card Association

 

Model No.

Sensor

TS40-5

TS40T-5

Frequency

40 kHz

Measurement range
(1/2 value for powder)

0.3 to 20

0.3 to 15m

Directive angle
(half of full angle)

12°(-6dB)
8°(-3dB)

22°(-6dB)
16°(-3dB)

Operation temperature

-20 to 70

Material

Epoxy/silicone/ PP

PVDF

Protection

IP68 equivalent

IP68 equivalent

Dimension (mm)

dia. 84x90

dia. 98x87

Sensor cable length

5m

Weight

500g

860g

Mounting screw

R1 (PT1)

G1 (PF1)


●TS40T-5 is chemical resistant.
●The sensors cannot be used in hydrofluoric acid environment.

* Contact us if sensor cable extension is required.